In this article, we learn how to connect to a Logix 5000 system using RSLinx Classic and Ethernet drivers.
#RSLINX CLASSIC LITE WINDOWS 10 DRIVERS#
Update: You can find the next part of the Learn Logix series, How to Use Ethernet Drivers with RSLinx Classic, here. If you haven’t already, be sure to subscribe to the mailing list below to be notified when the next part is available. In the next part of the series, we will learn how to connect to a Logix 5000 system using EtherNet/IP communication drivers. In this article, we learned how to connect to a Logix 5000 system using RSLinx Classic and a USB communication driver. We’ll learn how to work with EtherNet/IP drivers in the next lesson. To use the USB driver, you need direct access to the controller which is not always possible.įor permanent or remote connections, you need to use an EtherNet/IP connection to the controller or communications module. This is designed to be a temporary connection between a computer and a controller. The USB driver creates a point-to-point connection to a controller. Port Configuration Disadvantages of USB Drivers Once connected, a USB driver is automatically created in RSLinx Classic With RSLinx Classic open, connect your computer to a controller or communications module using a USB cable. This connection is a temporary point-to-point connection, it is not intended to create a permanent connection between a computer and a Logix 5000 system. The USB driver and virtual backplane are automatically created in RSLinx classic when you connect your computer to a Logix 5000 controller or communications module using a USB cable.
#RSLINX CLASSIC LITE WINDOWS 10 UPDATE#
Step 03) Based on my build of Windows 10, I'm going to need update KB4058258 which I can access by clicking on the helpful link shown above. Of the three driver types, USB drivers are the easiest to understand and work with. Step 02) Next, look up your version of Windows in Rockwell's free Tech Note HERE. Commonly, this programs installer has the following filenames: RSLINX.EXE and RSLINXCP.EXE etc. The software relates to Internet & Network Tools. The most popular versions of the tool are 4.0, 2.52 and 2.6.


#RSLINX CLASSIC LITE WINDOWS 10 INSTALL#
You can install this PC program on Windows XP/Vista/7/8/10 32-bit. There are three main driver types used to communicate with a Logix 5000 controller. You can download RSLinx Classic 4.00.1 from our software library for free. In this part of the series, we’ll learn how to use USB drivers to connect to a Logix 5000 system through RSLinx Classic. In the last part of the series, we got an introduction to RSLinx Classic, the software tool used to configure communication drivers with a Logix 5000 system. Disable for DHCP, this will allow Static IP AddressĢ.3.1.Learn Logix is a series of articles designed to teach you everything you need to know to work with Rockwell Automation’s Studio 5000 Logix Designer and the Logix 5000 series of PLCs. For Static IP address go to the “Comm Configure tab” in the RHEONICS CONTROL PANEL in the Ethernet section click the dropdown menu in DHCP and select false (This will disable DHCP function)įigure 2. Configuration in RHEONICS CONTROL PANEL to use Ethernet IP with DHCP.Ģ.3. Click on the “Update SMET” button to upload the new settings into the SMETįigure 1. Go to the “Comm Configure tab” in the RHEONICS CONTROL PANEL in the Ethernet section input all the parameters.Ģ.2.2. Figure 1 shows a standard configuration that can be used for the correct performance of the system. Open RHEONICS CONTROL PANEL software and configure the RHEONICS CONTROL PANEL to use DHCP. We recommend using an Ethernet Switch.Ģ.2. Connect Rheonics sensor, PLC, and PC (with RHEONICS CONTROL PANEL software installed) with an Ethernet Cable.